The Importance of Material Testing Using IZOD/Charpy Impact Tester

Comments ยท 337 Views

Plastic products are widely used in different industries to store and deliver products accurately. The failure of these materials will lead to damage and can hamper the quality of products. Thus, we at Presto have designed a high-quality IZOD/Charpy Impact Tester NXG model that has been us

Plastic products are widely used in different industries to store and deliver products accurately. The failure of these materials will lead to damage and can hamper the quality of products. Thus, we at Presto have designed a high-quality IZOD/Charpy Impact Tester NXG model that has been used to evaluate the impact resistance of plastics under sudden falling force or impact.

This next-generation model of this quality lab testing instrument can test different properties of the materials such as toughness, ductility, brittleness, and strength. The digital display incorporated into this izod impact will allow the users to view the impact/absorbed energy and angle of the test specimen. This is a valuable tool for understanding the performance of the specimen under a sudden impact force.

Besides this, the NXG model of the IZOD/CHARPY impact tester has been embedded with Strong gripping fixtures for charpy and izod test. It works on an Electromagnetic Pendulum release mechanism and has an inbuilt calibration facility that will make it easy for the machine to run smoothly and give accurate testing results every time.

This lab testing instrument comes complete with Instruction Manual, Electrical Wiring Diagram, and Calibration Certificate traceable to NABL-approved labs.

Features of IZOD/Charpy Impact Tester NXG

This new model of Izod impact resistance tester has been equipped with a high set of features that makes it easy for manufacturers to conduct the impact resistance test on plastics. The machine is designed in such a way that it can accurately measure the impact resistance of plastics with ease and accuracy.

  • Display for impact/absorbed energy and angle of the test specimen

  • Touch Screen display for accurate test results

  • Separate fixtures for Izod and Charpy test.

  • Highly accurate test results under impact forces.

  • Strong gripping fixtures for Izod/Charpy tests.

  • The electromagnetic Pendulum release mechanism

  • Inbuilt calibration facility

  • The graph test report is Energy Vs Angle

  • Data can be tabulated in excel format

  • Inbuilt hardware/software

  • Calibration lock & key feature

  • Real-time editable Excel test report

  • Test Report in PDF format.

Computer & Printer not a part of the offer

Technical specifications

  • Multiple test units: Joule/ m & kg-cm / cm

  • Capacity: Up to 21.68 Joules

  • Display: Touch Screen 4.3 “ TFT LCD

  • Accuracy: ± 2% within the entire range

  • Resolution: R1-0.02, R2-0.05, R3-0.1, R4-0.2 J respectively

  • Power: 220V AC, 5 Amp, Single phase, 50 Hz

  • The release angle of the pendulum: 150º

  • The radius of Izod Hammer: 0.79 ± 0.12 mm

  • The radius of Charpy Hammer: 3.17 ± 0.12 mm

Difference Between Izod And Charpy Test

Difference Between Izod And Charpy Test There are two types of testing methods which are used for evaluating the impact resistance of any material. One is ‘IZOD impact resistance test’ and another one is ‘izod and charpy impact test’. Both of them are based on the same principle but still are different in the way the tests are conducted. In this blog section, we will discuss these difference in details and will introduce you to an instrument suitable for both testing methods.

The major differences between both the testing techniques to keep in mind while selecting a test are as follows:

  • Specimen Position

The position of the specimen is different in both the testing methods. In the IZOD method, the test material is to be placed in a vertical position, while in the Charpy method, the test material will be placed horizontally.

  • Striking Point

The point at which the hammer will strike the specimen is distinct for both of them. In vertical testing, the hammer will strike on the upper tip of the sample while in horizontal testing the hammer will strike at the point of notch but in the opposite direction.

  • Notch Direction

The notch direction at which the sample will face is different in both the technique. The notch face in the IZOD test is facing the striker, fastened in a pendulum, while in the Charpy test, the notch face is situated away from the striker.

  • Specimen Dimensions

The test sample must have distinct dimensions for each test. The IZOD test specimen is 75 x 10 x 10mm and the basic Charpy test specimen is 55 x 10 x 10mm (the dimension can vary)

One of the renowned testing instrument offering both the techniques in one is IZOD/CHARPY Impact Tester Digital. It is designed to compute the impact resistance of plastics and metal. It works on the principle of the pendulum method. The instrument complies with ASTM D256 – 10, ASTM D618 – 13, ASTM D883 – 12, ASTM D1204 – 14, ASTM D1248 – 12, ASTM E691 – 14 standards.

 

Comments